Docklands Light Railway operates a self enforced noise and vibration policy which all sections of the line, including new extensions, are required to comply with.
Southdowns was appointed by the main construction contractor’s consulting engineers to undertake detailed modelling of groundborne vibration and structure radiated noise from elevated and retained cutting sections of the new line.
The detailed modelling was based upon a finite difference method of calculating the propagation of groundborne vibration through known ground types and strata, using a conservative vibration forcing function
and wheel/rail roughness profiles.

Representative sections of the viaduct structure were input into the model and a variety of operational scenarios were investigated to establish the structure’s response and the resulting structure radiated noise levels at a selection of distances from the viaduct.

Further studies were carried out on the potential enhanced structure radiated noise levels from high sided noise barriers proposed to mitigate airborne noise from running trains and which were to be installed on sections of the viaduct deck edges.

At the Airport end of the new extension, the railway runs into a retained cutting or trough structure. Groundborne vibration modelling was conducted to establish potential impacts at nearby residential dwellings.
The modelling of both groundborne vibration and structure radiated noise was used to determine the generic type of track form mitigation required to meet the Policy standards.
Southdowns provided recommended performance specifications for the required track form mitigation for both elevated viaduct and trough sections of the route to comply with DLR’s policy.

Croydon Tramlink Extension
Crossrail - Parliamentary Select Committee
Channel Tunnel Rail Link Contractors
West Coast Route Modernisation - Electrification Equipment
Southern Railway Train Operating Company
Thameslink Programme - CTRL Enabling Works
Southern Region Power Upgrade
Westminster City Council Rail Schemes Advice
Channel Tunnel Rail Link - Rail Link Engineering
St Louis Power Station, Mauritius
West Coast Route Modernisation - Contractor
DLR Woolwich-Arsenal Extension
Lincoln Station Re-modelling
DLR Langdon Park Station
St Pancras International Station
High Speed 1 - Tunnel Ventilation Shafts
Tottenham Court Road Station Upgrade
London Underground - Cooling the Tube Programme
East London Line Extension
Crossrail
Haripur Power Station, Bangladesh
Biomass Scheme, Polegate
Temporary Construction Railway - DLR Woolwich Ext.
Cambridge Junction, Hitchin
Network Rail Framework
Crossrail Bill
DLR Woolwich Extension Unveiled
Railway Procurement Agency - Rep. of Ireland
Bond Street Station Upgrade
southdowns_general.pdf
southdowns_highspeed.pdf
southdowns_crossrail_contractors_Oct2010.pdf
southdowns_railways.pdf
© Southdowns Environmental Consultants Ltd
MAIN OFFICE
16 Station Street, Lewes,
East Sussex, BN7 2DB, UK
Tel: +44 (0)1273 488186
Fax: +44 (0)1273 488187
Reg No. 3150111
LONDON OFFICE
10 Greycoat Place, London
SW1 1SB, UK
Tel: +44 (0)207 9606255