Biomass Scheme, Polegate

Southdowns were commissioned to assess noise impacts from the proposed construction and operation of a biomass facility on land adjacent to an existing wood transfer station near Polegate East Sussex.

The proposed development consisted of multiple noise sources including storage and handling areas, gasification plant, multiple gas engine generator units, a steam turbine, an outdoor discharge stack and a hybrid water cooling tower.

To calculate surrounding receptor noise levels, detailed noise modelling was undertaken which incorporated octave band noise data from the anticipated plant and activities associated with the development, the surrounding topography and noise barriers. The SoundPLAN noise software allowed interrogation of the receiver noise levels to determine which items of plant required additional mitigation.






On behalf of the client, Southdowns also liaised with the District and County Councils with regard to noise criteria and assessment requirements and were able to attend meetings with the County council to present calculations and report findings.

Related services

Mitigation Design
Industrial / Commercial
Recycling and Waste Management

Related projects

Somerfield / Texaco Forecourt Equipment & Shops
West Coast Route Modernisation - Electrification Equipment
Khartoum North Power Station, Sudan
Haripur Power Station, Bangladesh
Docklands Light Railway - City Airport Extension
Channel Tunnel Rail Link - Rail Link Engineering
St Louis Power Station, Mauritius
Lewes Combined Sewer Outfall
AGT Pipelines Project
Environment Agency - Waste Facilities
Bacton Gas Terminal
Southern Water Upgrades
Lidsey Landfill Site, West Sussex
Former Trico Site, Dunstable
East Cowes IOW - SEEDA
Bracknell Town Centre Masterplan
Pompey Village Portsmouth FC
DLR Woolwich-Arsenal Extension
Biomass Power Plant, Scotland
Marchwood Power Station
London Underground - Cooling the Tube Programme
Crossrail - Parliamentary Select Committee
Preston City Centre Re-Development
Trafalgar Way, Mixed Use Development, Docklands
High Speed 1 - Tunnel Ventilation Shafts
East London Line Extension
Newhaven Energy Recovery Facility
Super Materials Recovery Facility, Wembley
Landfill Site, Stanwell Moor
Coal Bed Methane Drilling

Related downloads

southdowns_general.pdf

© Southdowns Environmental Consultants Ltd

MAIN OFFICE
16 Station Street, Lewes,
East Sussex, BN7 2DB, UK

Tel: +44 (0)1273 488186
Fax: +44 (0)1273 488187

Reg No. 3150111

LONDON OFFICE

10 Greycoat Place, London
SW1 1SB, UK

Tel: +44 (0)207 9606255

Contact Us






website by BoxStuff