Southdowns was commissioned to undertake a noise audit at the St Louis Power Station in Mauritius and to recommend options for noise mitigation.
The requirement for this work was identified following an assessment of potential noise impacts associated with the installation of three new engines at the site and an Enforcement Notice served by the Mauritius Ministry of Environment in respect of noise pollution from existing power station operations.
The first stage of the assessment was to measure the existing noise levels generated by the Power Station both inside and outside the site boundaries. Particular consideration was given to the nearby adjacent residential areas which in some locations were as close as 10 metres to the power station.
Source term noise level measurements of major power station sources were also undertaken to establish the dominant plant and breakout noise from various building elements. Due to the high reverberant noise levels encountered within the engine halls it was necessary to use a sound intensity meter to isolate the noise levels of specific plant.
The survey results were used in conjunction with a computer model of the Power Station, to aid in the development of a noise mitigation strategy. This technique allowed various mitigation options to be tested and noise contours to be produced to assess compliance with the residential noise criteria.
The work also involved cost benefit analysis of the various mitigation strategies that were recommended. This included cost estimations for specific items such as splitter silencers, exhaust silencers, louvred enclosures, low noise fans and the shipping and installation costs of each option. Costs for the attenuation of specific power station sources were also assessed against the cost of construction of a 10 metre high boundary wall to screen the power station noise from adjacent residential properties.
Asset Management / Nuisance
Mitigation Design
Industrial / Commercial
Somerfield / Texaco Forecourt Equipment & Shops
West Coast Route Modernisation - Electrification Equipment
Southern Railway Train Operating Company
Khartoum North Power Station, Sudan
Haripur Power Station, Bangladesh
Docklands Light Railway - City Airport Extension
Channel Tunnel Rail Link - Rail Link Engineering
Lewes Combined Sewer Outfall
AGT Pipelines Project
Environment Agency - Waste Facilities
Bacton Gas Terminal
Southern Water Upgrades
Lidsey Landfill Site, West Sussex
Former Trico Site, Dunstable
East Cowes IOW - SEEDA
Bracknell Town Centre Masterplan
Pompey Village Portsmouth FC
DLR Woolwich-Arsenal Extension
Biomass Power Plant, Scotland
Marchwood Power Station
London Underground - Cooling the Tube Programme
Crossrail - Parliamentary Select Committee
Preston City Centre Re-Development
Trafalgar Way, Mixed Use Development, Docklands
High Speed 1 - Tunnel Ventilation Shafts
East London Line Extension
Newhaven Energy Recovery Facility
Super Materials Recovery Facility, Wembley
Biomass Scheme, Polegate
St Pancras International Station
Coal Bed Methane Drilling
Railway Procurement Agency - Rep. of Ireland
© Southdowns Environmental Consultants Ltd
MAIN OFFICE
16 Station Street, Lewes,
East Sussex, BN7 2DB, UK
Tel: +44 (0)1273 488186
Fax: +44 (0)1273 488187
Reg No. 3150111
LONDON OFFICE
10 Greycoat Place, London
SW1 1SB, UK
Tel: +44 (0)207 9606255